Voltage Power Regulator

MGR-HVR Series Voltage Power Regulator

[All the information on this website is for reference only, and the actual product and the accompanying product manual shall prevail. If you have any questions, please contact webmaster@huimultd.com]

Introduction


MGR-HVR Series Potentiometer Type Solid State Voltage Regulator uses Industrial Package (long strip shape). Through the adjustment of potentiometer, MGR-HVR Series can stepless control the load voltage of the single phase AC load. According to the output current, it can be divided into Normal Type and Large Current Type.

How to order


How to order MGR-HVR Series Voltage Power Regulator

MGR-HVR (Single Phase Potentiometer Type Voltage Regulator, Industrial Package)
  - [Rated Current]

Parameters


MGR-HVR Series img

MGR-HVR Series

Control Method:  Manual Control--Adjustable Potentiometer (470K, 680K, 820K)
Load Voltage:  0~480VAC (such as 24VAC, 36VAC, 48VAC, 110VAC/120VAC, 220VAC/230VAC, 480VAC or customized voltage)
Load Current:  60A, 80A, 100A, 120A, 125A
Dimensions & Mounting:  94mm*25mm*38mm; Panel mount solid state relay with metal base and screw terminals

MGR-HVR Series (Large Current) img

MGR-HVR Series (Large Current)

Control Voltage:  Manual Control--Adjustable Potentiometer (470K, 680K, 820K)
Load Voltage:  0~480VAC (such as 24VAC, 36VAC, 48VAC, 110VAC/120VAC, 220VAC/230VAC, 480VAC or customized voltage)
Load Current:  150A, 200A, 300A, 400A
Dimensions & Mounting:  94mm*34mm*42mm; Panel mount solid state relay with metal base and screw terminals

Features


● "Ultra-low" input current
● Low output off-state leakage current
● Low output on-state voltage drop
● Standard output RC snubber circuit
● Fully compatible with different control methods, allowing the computer to easily adjust voltage through the network

Dimensions and Circuit Wiring Diagram


MGR-HVR Series Voltage Power Regulator

MGR-HVR Series Voltage Power Regulator Normal Type Diagram

Normal Type

MGR-HVR Series Voltage Power Regulator Large Current Type Diagram

Large Current Type

Application


● Applications that need voltage adjustment.

Precautions and FAQs


● If the load current is 10A, a heat sink must be equipped; if the load current is 40A or more, an air-cooled radiator or a water-cooled radiator must be installed.
● When the load is an inductive load, be sure to connect a varistor in parallel with the output terminal, whose voltage value is 1.6-1.9 times the load voltage.
● What is the difference between a Standard Package SSR (TRIAC output) and an Industrial Package SSR (anti-parallel SCR output)?
For resistive AC loads, the difference between the two is small. Standard Package can use up to M5 screws, while Industrial Package can use up to M8 screws.
For inductive or capacitive AC loads, when the solid state relay is turned off in the on state, a large voltage-rise rate dv/dt (commutation dv/dt) will occur due to the inconsistent phase of the current and voltage. Such dv/dt affects the output efficiency of TRIAC, or even damages TRIAC, but the effect of commutation dv/dt on anti-parallel SCR is very small. Therefore, for AC loads with large inductance or capacitance, it is more suitable to choose industrial solid state relays.

All Regular Models We Offer


● MGR-HVR Series (Single Phase, Industrial Package)

Load Voltage 0~480VAC, Normal Type

Load Voltage 0~480VAC, Large Current Type

*Customized models are available, be free to contact us.

Tips

1) When selecting the rated current of the solid state relay/solid state module, please consider the corresponding Derating Factor.
2) You can visit Blog - Resource to view and download files.
3) You can visit Products to view and learn about other products.
4) You can visit Information to view and learn about solid state relays/solid state modules knowledge.
5) You can also visit Help, or Contact us to get more support.




  Get in touch with us now!


Please take a minute or two to complete this simple form to get reply in 24 hours, thank you!

*Please check the trash box of your mailbox, if you do not receive our email.